ScanExtractor
Class: maltcms.commands.fragments.preprocessing.ScanExtractor
Workflow Slot: GENERAL_PREPROCESSING
Description: Allows definition of a start and end modulation period to be extracted from a raw chromatogram.
Variables
Required
Optional
Provided
var.scan_index var.scan_acquisition_time var.mass_values var.intensity_values var.total_intensity
Configurable Properties
Name: endScan
Default Value: -1
Description:
The end index to include. A value of -1 will automtically select the last available index.
Name: endTime
Default Value: +Inf
Description:
The end time to include in scan extraction. If value is different from +Inf, endScan will be used instead.
Name: startScan
Default Value: -1
Description:
The start index to include. A value of -1 means to select the first start scan automatically.
Name: startTime
Default Value: -Inf
Description:
The start time to include in scan extraction. If value is different from -Inf, startScan will be used instead.